The webinar will focus on the importance of ensuring that the validation of an FDA-regulated computer system will meet compliance guidelines. This includes the development of a company philosophy and approach and incorporating it into an overall computer system validation program and plans for individual systems that are regulated by the FDA. It also requires a recognition that data integrity issues continue to be a strong area of focus by the FDA during the inspection, and there are many examples and best practices that will be covered in this seminar to address them.
FDA’s guidelines for computerized systems were enacted in 1983, and very little has changed, other than technology, since that time, as it relates to validation. The premise for compliance is demonstrating clearly and completely that a computer system does what it purports to do. This means developing a very detailed set of unique and testable functional requirements and creating a set of test scripts that will prove each requirement is met.
This webinar will describe the approach to determining the level and robustness of testing required, based on a thorough risk assessment of the system, which includes the likelihood, severity, and detectability of potential failures of the system to work as expected, and the mitigation to be applied, should the system fail. Along with system categorization, in accordance with GAMP 5 principles, and an evaluation of the complexity and application of the software, the attendee will understand how to develop the rationale they will include in the validation plan for the level of testing executed.
A company must have specific policies and procedures in place that explicitly state responsibilities and provide guidance for validation, which will be discussed. We will also delve into the training requirements for users, testers, and those who will be the stewards of the system. All must be carefully documented. Disaster recovery and Business Continuity Planning will also be touched upon as key aspects of supporting the system in a validated state. Change control and periodic review will address the challenges of making certain that the system remains in control and is tested further according to any needs that arise from changes.
As FDA continues to evolve and change due to the many factors that influence the regulatory environment, companies must be able to adapt. New technologies will continue to emerge that will change the way companies do business. While many of these are intended to streamline operations, reducing time and resources, some unintentionally result in added layers of oversight that encumber a computer system validation program and require more time and resources, making the technology unattractive from a cost-benefit perspective.
WHY SHOULD YOU ATTEND?
This webinar will help you understand in detail the application of FDA’s guidelines for Computer System Validation (CSV), which is per the System Development Life Cycle (SDLC) Methodology. This is critical to develop the appropriate validation strategy and achieve the thoroughness required to prove that a system does what it purports to do. It also ensures that a system is maintained in a validated state throughout its entire life cycle, from conception through retirement.
The SDLC will provide a framework for validation planning, allowing the attendee to understand all of the phases and deliverables required during validation.
The end result will be a very well documented validation effort that will stand up to FDA scrutiny during an audit, and assure that the data housed and/or processed using the validated computer system will be maintained with great integrity. It is important to remember that in addition to validating a computer system subject to FDA compliance, the system must be maintained in a validated state throughout its lifecycle until the system is retired or otherwise no longer used. This webinar will describe the policies, procedures, training and other underlying support elements that are needed to ensure ongoing maintenance of a system in a validated state.
In addition, FDA has heavily focused its resources on inspection targeting Data Integrity (DI). During the past ten years, the percentage of Form 483 citations and Warning Letters with issues related to DI has increased dramatically and continues to do so through 2019. We will provide the requirements related to DI, examples of FDA findings, and will cover the industry best practices that will help you mitigate this potential risk.
LEARNING OBJECTIVES
- Computer System Validation (CSV)
- System Development Life Cycle (SDLC) methodology
- Good “Variable” Practice (GxP) (Good Manufacturing Practice (GMP), Good Laboratory Practice (GLP), Good Clinical Practice (GCP))
- Data Integrity (DI)
- Validation strategy, planning, and execution
- System risk assessment
- GAMP 5 “V” Model and software categorization
- 21 CFR Part 11, FDA’s guidance on Electronic Records/Electronic Signatures (ER/ES)
- Security, access, change control, and audit trail
- Criteria required to ensure data is created and maintained with integrity through its life cycle
- Policies and Procedures to support CSV and DI assurance
- Training and organizational change management
- Current FDA trends in compliance and enforcement
- Industry best practices and common pitfalls
- Q&A
WHO WILL BENEFIT?
- Information technology managers, developers, and analysts
- QC/QA managers and analysts
- Clinical data managers and scientists
- Compliance managers
- Lab managers
- Automation analysts
- Computer system validation specialists
- GMP training specialists
- Business stakeholders and individuals who are responsible for computer system validation planning, execution, reporting, compliance, and audit
- Consultants working in the life sciences industry who are involved in computer system implementation, validation, and compliance
This webinar will help you understand in detail the application of FDA’s guidelines for Computer System Validation (CSV), which is per the System Development Life Cycle (SDLC) Methodology. This is critical to develop the appropriate validation strategy and achieve the thoroughness required to prove that a system does what it purports to do. It also ensures that a system is maintained in a validated state throughout its entire life cycle, from conception through retirement.
The SDLC will provide a framework for validation planning, allowing the attendee to understand all of the phases and deliverables required during validation.
The end result will be a very well documented validation effort that will stand up to FDA scrutiny during an audit, and assure that the data housed and/or processed using the validated computer system will be maintained with great integrity. It is important to remember that in addition to validating a computer system subject to FDA compliance, the system must be maintained in a validated state throughout its lifecycle until the system is retired or otherwise no longer used. This webinar will describe the policies, procedures, training and other underlying support elements that are needed to ensure ongoing maintenance of a system in a validated state.
In addition, FDA has heavily focused its resources on inspection targeting Data Integrity (DI). During the past ten years, the percentage of Form 483 citations and Warning Letters with issues related to DI has increased dramatically and continues to do so through 2019. We will provide the requirements related to DI, examples of FDA findings, and will cover the industry best practices that will help you mitigate this potential risk.
- Computer System Validation (CSV)
- System Development Life Cycle (SDLC) methodology
- Good “Variable” Practice (GxP) (Good Manufacturing Practice (GMP), Good Laboratory Practice (GLP), Good Clinical Practice (GCP))
- Data Integrity (DI)
- Validation strategy, planning, and execution
- System risk assessment
- GAMP 5 “V” Model and software categorization
- 21 CFR Part 11, FDA’s guidance on Electronic Records/Electronic Signatures (ER/ES)
- Security, access, change control, and audit trail
- Criteria required to ensure data is created and maintained with integrity through its life cycle
- Policies and Procedures to support CSV and DI assurance
- Training and organizational change management
- Current FDA trends in compliance and enforcement
- Industry best practices and common pitfalls
- Q&A
- Information technology managers, developers, and analysts
- QC/QA managers and analysts
- Clinical data managers and scientists
- Compliance managers
- Lab managers
- Automation analysts
- Computer system validation specialists
- GMP training specialists
- Business stakeholders and individuals who are responsible for computer system validation planning, execution, reporting, compliance, and audit
- Consultants working in the life sciences industry who are involved in computer system implementation, validation, and compliance
Speaker Profile
Carolyn Troiano has more than 35 years of experience in computer system validation in the tobacco, pharmaceutical, medical device and other FDA-regulated industries. She has worked directly, or on a consulting basis, for many of the larger pharmaceutical and tobacco companies in the US and Europe. She is currently building an FDA computer system validation compliance strategy at a vapor company. Carolyn has participated in industry conferences, and is currently active in the Association of Information Technology Professionals (AITP), and Project Management Institute (PMI) chapters in the Richmond, VA area. Carolyn also volunteers for the PMI’s Educational Fund as a …
Upcoming Webinars
Understanding and Analyzing Financial Statements
Onboarding is Not Orientation: How to Improve Your New Hire…
Managing Toxic & Other Employees Who have Attitude Issues
Do's and Don'ts of Documenting Employee Behaviour, Performa…
Gossip-Free: Leadership Techniques to Quell Office Chatter
Outlook - Master your Mailbox - Inbox Hero Inbox Zero
Harassment, Bullying, Gossip, Confrontational and Disruptiv…
Excel & ChatGPT Synergy Masterclass: Unleashing Financial A…
Introduction to Microsoft Power BI Dashboards
Drive Recruiting Success with the Using Recruiting Metrics …
2025 EEOC & Employers: Investigating Claims of Harassment …
Impact Assessments For Supplier Change Notices
Mastering Job Descriptions: Legal and Practical Insights fo…
Effective Onboarding: How to Welcome, Engage, and Retain Ne…
What is in Store for Employers When Updating Employee Handb…
Designing Employee Experiences to Build a Culture of Compli…
Onboarding Best Practices for 2025: Proven Strategies to Po…
Accounting For Non Accountants : Debit, Credits And Financi…
Creating a Successful Job Rotation Program
The Anti-Kickback Statute: Enforcement and Recent Updates
FDA Compliance And Laboratory Computer System Validation
How To Create Psychological Safety in your Organization
Aligning Your HR Strategy with Your Business Strategy
Transforming Anger And Conflict Into Collaborative Problem …
How to Give Corrective Feedback: The CARE Model - Eliminati…
I-9 Audits: Strengthening Your Immigration Compliance Strat…
Zero Acceptance Sampling to Reduce Inspection Costs
Identifying, Managing, and Retaining High Potential Employe…
AI at Your Service: Enhancing Your Microsoft OfficeSkills w…
Why EBITDA Doesn't Spell Cash Flow and What Does
FDA Recommendations for Artificial Intelligence/Machine Lea…
Project Management for Non-Project Managers - How to commun…
Dealing With Difficult People In Life & Work
Developing and Implementing Quality Culture in the Organiza…
2-Hour Virtual Seminar on the 6 Most Common Problems in FDA…
Enhancing Pivot Tables with Images: Visualize Your Data Lik…
How to Write Effective Audit Observations: The Principles f…
How to Write Contracts for Procurement Professionals
Uplifting the Credibility of HR: How to Build the Credibili…
Strategic Interviewing & Selection: Getting the Right Talen…
Performance of Root Cause Analysis, CAPA, and Effectiveness…
FDA Audit Best Practices - Do's and Don'ts
Unlock Employee Loyalty: Stay Interviews Will Keep Them Eng…
How to Manage the Legal Landmine of the FMLA, ADA and Worke…
Excel Lookup Functions: VLOOKUP, HLOOKUP, and XLOOKUP Made …